2 Channel Electrochemical Workstation
video

2 Channel Electrochemical Workstation

Model: TOB-CS-2350
TOB-CS-2350 bipotentiostat is developed from single channel TOB-CS-350 potentiostat/galvanostat. There are two s ets of built-in potentiostat /galvanostat. The two channels can conduct same or different experiments ind ependently/simultaneously.
Αποστολή ερώτησής
Chat τώρα
Εισαγωγή προϊόντος

 

2 Channel Electrochemical Workstation

 

 

TOB-CS-2350 bipotentiostat is developed from single channel TOB-CS-350 potentiostat/galvanostat. There are two s ets of built-in potentiostat /galvanostat. The two channels can conduct same or different experiments ind ependently/simultaneously. If the user only chooses to use the main channel, thenTOB-CS-2350 turns to be aTOB-CS-350. Apart from all functi ons thatTOB-CS-350 single-channel potentiostat has,TOB-CS-2350 can especially be used to do RRDE and HDT.

 

(1) Electrosythesis, electrodeposition (electroplating), anodic oxidation, electrolysis

(2) Oxygen reduction reaction(ORR), oxygen evolution reaction (OER), Hydrogen evolution reaction(HE R), carbon dioxide reduction.

(3) Energy and materials (Li-ion battery, solar cell, fuel cell, supercapacitor), advanced function materials, and sensor.

(4) Corrosion behavior of metals, and anti-corrosion evaluation

(5) Fast evaluation of inhibitor, water quality stabilizer, coating, and cathodic protection efficiency.

 

Rotating ring-disk electrode(RRDE)

 

Two potentiostats are combined with Devnathan-Stachurski (dual cell). By measuring cathode hydrogen charging (the left cell) and anode oxidation current of hydrogen atoms (the right cell), it can further calcul ate the diffusion coefficient of hydrogen atoms in the metal and hydrogen flux.

 

Main Channel: ± 10V
Slave Channel: ± 10V
± 1A
0. 1 percent ×full range±1mV
0. 1 percent ×full range
10μV (>100Hz), 3 μV (<10Hz)
1pA
< 1 μs (<10mA), < 10μs (<2A)
1012Ω||20pF
2A~2nA, 10 ranges
±21V
1A
0.001mV~ 10,000V/s
0.0001~65,000s
1mA@1A/ms
0.076mV@ 1V/ms
0.001~ 100 kHz
0.0001~ 1000s
16bit@1 MHz,20bit@1 kHz
16bit, setup time:1 μs
0.075mV
10μ Hz~ 1MHz
Low-pass filters Covering 8-decade
10μ Hz~ 1MHz
0mV~2500mV
-10V ~ plus 10V
50Ω
< 1%
1nF ;Maximum load inductance:10μ H
10ms or the longest time of a cycle
106 cycles or 105s
0~ 105s
-10V ~ plus 10V
- 1A~ plus 1A
8-decade frequency range, Automatic and manual setting
isolated Universal Serial Bus (USB 2.0)
Windows 2000/NT/XP/7/8/10

 

Electrochemical Workstation

Electrochemical Workstation

Electrochemical Workstation

Electrochemical Workstation

Electrochemical Workstation

 

patent certificate

ISO 9001

ISO 9001

ce certificate

 

 

Δημοφιλείς Ετικέτες: 2 channel electrochemical workstation, suppliers, manufacturers, factory, price

Αποστολή ερώτησής

whatsapp

Τηλέφωνο

Ηλεκτρονικό ταχυδρομείο

Εξεταστική